Surgery
Class ProsthesisInstalled

Information related to the prosthesis used for this operative procedure. [FileMan 130,.47]

Attributes
ImplantedDevice implantedDevice implantedDevice

Pointer to the implanted prosthetic device required for this operative procedure. [FileMan 130,.47->130.01,.01]

«CS» Code quantity quantity

The quantity of this prosthetic device used for this operative procedure. [FileMan 130,.47->130.01,7]

«TS» PointInTime sterilityExpirationDate sterilityExpirationDate

The sterility expiration date. [FileMan 130,.47->130.01,9]

PractitionerParticipation sterilityVerifier sterilityVerifier

The person (typically a registered nurse) that verified the sterility information. [FileMan 130,.47->130.01,10]

«CS» Code sterilizationResponsibility sterilizationResponsibility

Categorizes who was accountable for the sterilization of the prosthetic device. Possible values include: Manufacturer; SPD; Surgery. [FileMan 130,.47->130.01,5]

Boolean wasReadBackPerformed wasReadBackPerformed

An additional step is performed immediately prior to the implantation of the medical device. The privileged provider performing the procedure must confirm the correct implant with a team member, including a "read-back" of all relevant information. For Ophthalmologic intraocular lens implant procedures, the immediate intra-operative pre-implant "read-back" must include intraocular lens implant style, power and expiration date. [FileMan 130,.47->130.01,13]

«CS» Code wasSterilityChecked wasSterilityChecked

Indicates whether or not the implant sterility was checked. [FileMan 130,.47->130.01,8]


Properties:

Alias
Classifier Behavior
Is Abstractfalse
Is Activefalse
Is Leaffalse
Keywords
NameProsthesisInstalled
Name Expression
NamespaceSurgery
Owned Template Signature
OwnerSurgery
Owning Template Parameter
PackageSurgery
Qualified NameFHIM::Surgery::ProsthesisInstalled
Representation
Stereotype
Template Parameter
VisibilityPublic

Attribute Details

 implantedDevice
Public ImplantedDevice implantedDevice

Pointer to the implanted prosthetic device required for this operative procedure. [FileMan 130,.47->130.01,.01]

Constraints:
Properties:

AggregationNone
Alias
AssociationprosthesisInstalled_implantedDevice
Association End
ClassProsthesisInstalled
Datatype
Default
Default Value
Is Compositefalse
Is Derivedfalse
Is Derived Unionfalse
Is Leaffalse
Is Orderedfalse
Is Read Onlyfalse
Is Staticfalse
Is Uniquetrue
Keywords
Lower1
Lower Value(1)
Multiplicity1
NameimplantedDevice
Name Expression
NamespaceProsthesisInstalled
Opposite
OwnerProsthesisInstalled
Owning Association
Owning Template Parameter
Qualified NameFHIM::Surgery::ProsthesisInstalled::implantedDevice
Stereotype
Template Parameter
TypeImplantedDevice
Upper1
Upper Value(1)
VisibilityPublic


 quantity
Public «CS» Code quantity

The quantity of this prosthetic device used for this operative procedure. [FileMan 130,.47->130.01,7]

Constraints:
Properties:

AggregationNone
Alias
Association
Association End
ClassProsthesisInstalled
Datatype
Default
Default Value
Is Compositefalse
Is Derivedfalse
Is Derived Unionfalse
Is Leaffalse
Is Orderedfalse
Is Read Onlyfalse
Is Staticfalse
Is Uniquetrue
Keywords
Lower0
Lower Value(0)
Multiplicity0..1
Namequantity
Name Expression
NamespaceProsthesisInstalled
Opposite
OwnerProsthesisInstalled
Owning Association
Owning Template Parameter
Qualified NameFHIM::Surgery::ProsthesisInstalled::quantity
Stereotype
Template Parameter
Type«CS» Code
Upper1
Upper Value(1)
VisibilityPublic


 sterilityExpirationDate
Public «TS» PointInTime sterilityExpirationDate

The sterility expiration date. [FileMan 130,.47->130.01,9]

Constraints:
Properties:

AggregationNone
Alias
Association
Association End
ClassProsthesisInstalled
Datatype
Default
Default Value
Is Compositefalse
Is Derivedfalse
Is Derived Unionfalse
Is Leaffalse
Is Orderedfalse
Is Read Onlyfalse
Is Staticfalse
Is Uniquetrue
Keywords
Lower0
Lower Value(0)
Multiplicity0..1
NamesterilityExpirationDate
Name Expression
NamespaceProsthesisInstalled
Opposite
OwnerProsthesisInstalled
Owning Association
Owning Template Parameter
Qualified NameFHIM::Surgery::ProsthesisInstalled::sterilityExpirationDate
Stereotype
Template Parameter
Type«TS» PointInTime
Upper1
Upper Value(1)
VisibilityPublic


 sterilityVerifier
Public PractitionerParticipation sterilityVerifier

The person (typically a registered nurse) that verified the sterility information. [FileMan 130,.47->130.01,10]

Constraints:
Properties:

AggregationNone
Alias
Association
Association End
ClassProsthesisInstalled
Datatype
Default
Default Value
Is Compositefalse
Is Derivedfalse
Is Derived Unionfalse
Is Leaffalse
Is Orderedfalse
Is Read Onlyfalse
Is Staticfalse
Is Uniquetrue
Keywords
Lower0
Lower Value(0)
Multiplicity0..1
NamesterilityVerifier
Name Expression
NamespaceProsthesisInstalled
Opposite
OwnerProsthesisInstalled
Owning Association
Owning Template Parameter
Qualified NameFHIM::Surgery::ProsthesisInstalled::sterilityVerifier
Stereotype
Template Parameter
TypePractitionerParticipation
Upper1
Upper Value(1)
VisibilityPublic


 sterilizationResponsibility
Public «CS» Code sterilizationResponsibility

Categorizes who was accountable for the sterilization of the prosthetic device. Possible values include: Manufacturer; SPD; Surgery. [FileMan 130,.47->130.01,5]

Constraints:
Properties:

AggregationNone
Alias
Association
Association End
ClassProsthesisInstalled
Datatype
Default
Default Value
Is Compositefalse
Is Derivedfalse
Is Derived Unionfalse
Is Leaffalse
Is Orderedfalse
Is Read Onlyfalse
Is Staticfalse
Is Uniquetrue
Keywords
Lower0
Lower Value(0)
Multiplicity0..1
NamesterilizationResponsibility
Name Expression
NamespaceProsthesisInstalled
Opposite
OwnerProsthesisInstalled
Owning Association
Owning Template Parameter
Qualified NameFHIM::Surgery::ProsthesisInstalled::sterilizationResponsibility
Stereotype
Template Parameter
Type«CS» Code
Upper1
Upper Value(1)
VisibilityPublic


 wasReadBackPerformed
Public Boolean wasReadBackPerformed

An additional step is performed immediately prior to the implantation of the medical device. The privileged provider performing the procedure must confirm the correct implant with a team member, including a "read-back" of all relevant information. For Ophthalmologic intraocular lens implant procedures, the immediate intra-operative pre-implant "read-back" must include intraocular lens implant style, power and expiration date. [FileMan 130,.47->130.01,13]

Constraints:
Properties:

AggregationNone
Alias
Association
Association End
ClassProsthesisInstalled
Datatype
Default
Default Value
Is Compositefalse
Is Derivedfalse
Is Derived Unionfalse
Is Leaffalse
Is Orderedfalse
Is Read Onlyfalse
Is Staticfalse
Is Uniquetrue
Keywords
Lower0
Lower Value(0)
Multiplicity0..1
NamewasReadBackPerformed
Name Expression
NamespaceProsthesisInstalled
Opposite
OwnerProsthesisInstalled
Owning Association
Owning Template Parameter
Qualified NameFHIM::Surgery::ProsthesisInstalled::wasReadBackPerformed
Stereotype
Template Parameter
TypeBoolean
Upper1
Upper Value(1)
VisibilityPublic


 wasSterilityChecked
Public «CS» Code wasSterilityChecked

Indicates whether or not the implant sterility was checked. [FileMan 130,.47->130.01,8]

Constraints:
Properties:

AggregationNone
Alias
Association
Association End
ClassProsthesisInstalled
Datatype
Default
Default Value
Is Compositefalse
Is Derivedfalse
Is Derived Unionfalse
Is Leaffalse
Is Orderedfalse
Is Read Onlyfalse
Is Staticfalse
Is Uniquetrue
Keywords
Lower0
Lower Value(0)
Multiplicity0..1
NamewasSterilityChecked
Name Expression
NamespaceProsthesisInstalled
Opposite
OwnerProsthesisInstalled
Owning Association
Owning Template Parameter
Qualified NameFHIM::Surgery::ProsthesisInstalled::wasSterilityChecked
Stereotype
Template Parameter
Type«CS» Code
Upper1
Upper Value(1)
VisibilityPublic